Menu

About Positive Pressure

LiveO2 does not use Positive Pressure because:

  1. Positive pressure would inhibit gas exchange in the lungs and reduce waste gas removal
  2. Positive pressure would reduce the strengthening effect LiveO2 users achieve with extra air flow resistance
  3. Positive pressure would reduce the exertion effect that enables LiveO2 to produce benefits in handicapped users
  4. Positive pressure would likely cause LiveO2 to be classified as a breathing assistance device

Breathing Mechanics

A simple way to look at it is to look in the mirror. Why did nature make your nostrils smaller than your mouth?

 

Diagram of the alveolus in the lungs showing gaseous exchange.

Nostrils

It’s simple. Your nostrils are smaller because airflow resistance is an important part of breathing. That’s why it’s natural to breathe through your nose instead of your mouth.

Respiration is a cycle:

  1. Rest between breaths with lungs empty
  2. Inhale starts when CO2 drives blood acidic
  3. Inhalation vacuum pulls the CO2 & waste gasses out of the blood through the alveolar membrane
  4. Exhale pressure pushes oxygen across the alveolar membrane into the blood
  5. We rest with lungs empty until we need another breath

Even though we don’t think about it, bodies naturally regulate airflow resistance to optimize gas transfer.

We use several reflexes:

Breathing through the nose creates airflow for inhale and exhale like nature intended.

The Role Airflow Resistance

We use airflow resistance instinctively:

Both reflexes increase airflow resistance during breath but they have other effects too.

During Inhale

Inhale resistance creates two specific effects:

  1. Respiration Structure

    Vacuum pulls waste gas out of the blood. Waste gas is mostly carbon dioxide, but includes other gasses and toxins. More resistance creates more vacuum and helps our bodies eliminate waste.

  2. Inhalation resistance causes the chest to pull harder which strengthens breathing muscles. This resistance tends to strengthen a users from loss of strength in breathing muscles from long-term sedentary lifestyles.
  3. Inhalation resistance adds to the physical work load of exercise.

During Exhale

Exhale force pushes oxygen into the blood to attach to hemoglobin and to dissolve in blood plasma. Both are important but the increase in blood plasma oxygen concentration is critical.

We instinctively supplement normal exhalation resistance by blowing through the lips to boost back pressure to push more oxygen into the blood.

Exhalation resistance adds to the physical work load of exercise.

Bad Breath

Waste gasses cause breath odor. When you inhale the vacuum created in the alveoli pulls these gasses out of the blood.

Someone that exercises is less likely to have bad breath.

This is because stronger and more frequent vacuum cycle pulls out more waste gas. Exercise circulates much more blood through the lungs with higher vacuum removing more waste gas.

Extra inhalation resistance during inhale helps the body pull more waste gasses out of the blood making breathing more effective for waste gas elimination.

About LiveO2 Airflow Resistance

LiveO2 is a Neutral Pressure ™ breathing system because LiveO2 is intended to work with nature.

It took us quite a while to understand the how the mechanics of LiveO2 helped breathing. We were surprised to discover that airflow resistance was important to both oxygen absorption and waste gas release.

Airflow resistance is a big part of breathing efficiency:

  1. Inhalation resistance improves waste gas removal
  2. Inhalation resistance strengthens inhale muscles
  3. Inhalation resistance adds to the physical during exercise
  4. Exhalation resistance increases the oxygen that attaches to hemoglobin in red blood cells
  5. Exhalation resistance increases the oxygen partial pressure in blood plasma
  6. Exhalation resistance increases physical work during exercise.

Each one of these elements is a reason NOT to interfere with nature and to encourage airflow resistance.’

Handicapped Users

When we started working with paralyzed clients we realized that the physical the work effect of breathing was important too.

People that lack control of large muscles need the work effect of breathing against a resistance. This turned out to be one reason LiveO2 worked so well for disabled users.

Our Basic Mask System

The LiveO2 Standard Mask has a 3/4 inch diameter inflow port which enables most users to inhale without noticeable airflow resistance at rest.

Under load this small diameter port creates a mild additional inhalation resistance.

Eventually we came to understand that this mild resistance contributed to the good results even though it added a mild discomfort.

Strong breathers didn’t notice airflow resistance and actually like it. Weak breathers dislike it but need it because they are weak breathers and need to get stronger.

Our dilemma was that airflow resistance was both a benefit and a nuisance. What should we do?

We discovered that any sort of positive pressure in the breathing circuit would reduce benefits of LiveO2.

We eventually decided to offer two mask systems to enable our users to optimize comfort:

We also chose NOT to implement any sort of positive pressure because that feature contradicts the instinctive science of effective breathing.

Regulations of Pressurized Breathing Systems

Positive pressure features suggest the device is intended to assist a user with breathing.

We also avoided any sort of positive pressure because the rules and regulations that govern oxygen delivery equipment define any device with positive pressure as a medical device. These devices have the apparent intent of providing breathing assistance to a user, like a CPAP machine.

LiveO2 does not cross the line from passive to an active breathing device on purpose. LiveO2 is intended marketed an exercise device not a medical breathing apparatus. It does not provide positive pressure to avoid usage restrictions which would apply to a pressurized breathing apparatus.

Additionally there are specific labeling requirements for pressurized oxygen storage. The regulations do not specify how much pressure is required for a device to be considered pressurized.

Absent pressure, LiveO2 customers avoid more specific rules and regulations that apply to pressurized oxygen delivery systems.